Resonance in a Drilling Pump
Vibration analysis on a drilling pump identified resonance that drove abnormal motion. We defined corrective actions that removed the issue and stabilized operation.
Mechanical Looseness at Fan Base
Process fan vibration traced to poor base design with missing diagonal bracing. Reinforcement restored stiffness, lowered vibration, and improved reliability.
Blower Vibration Investigation
Blower vibration traced to motor soft foot that mimicked unbalance. Fixing base flatness avoided needless motor replacement and cut vibration to stable levels.
Resonance in Lubricating Oil Piping
Vibration in a lubricating oil line was linked to piping resonance. We defined supports and layout corrections that removed excitation and stabilized the system.
Resonance in a Turbine Turning Gear Motor
Turning gear motor had repeat bearing failures. Diagnostics found resonance at turbine speed while idle. Corrective tuning prevented brinelling and restored life.
Resonance in an Extruder Head
Extruder head resonance caused vibration and contamination in clear polycarbonate. We set corrective actions that removed resonance and restored product quality.
Gas Leak in an Agitated Reactor
Failure study on an agitated reactor traced gas leakage to sealing weaknesses. Actions restored sealing integrity, stabilized operation, and reduced safety risk.
Deficient Pump Motor Base Design
Pump motor base design and anchoring were inadequate. Recommendations covered stiffening, proper grouting and leveling, correct anchor bolts, and precise alignment.
Mechanical Looseness Between Blower Base and Support Frame
Mechanical looseness at the interface between blower base and frame raised vibration. Regrouting, leveling, proper anchoring, and added bracing restored stiffness.
Poor Piping Layout and Flow Design
Pump and line vibration traced to poor piping route and flow conditions. Rerouting, better supports, and correct reducer orientation reduced turbulence and loads.
Deficient Extruder Base Design
Under designed extruder base produced elevated vibration. Reinforcement, proper grouting and leveling, correct anchor bolts, and shaft alignment restored stability.
Mechanical Looseness at Machine Base
Mechanical looseness at the machine base and foundation interface raised vibration. Regrouting, leveling, and correct preload returned smooth and reliable operation.
Mechanical Looseness in the Machine Frame
Looseness within frame members and joints reduced stiffness and raised vibration. Weld repairs, fastener replacement and added gussets restored structural integrity.